Theranostics 2019; 9(26):8239-8252. doi:10.7150/thno.37672 This issue Cite

Research Paper

A 25 micron-thin microscope for imaging upconverting nanoparticles with NIR-I and NIR-II illumination

Hossein Najafiaghdam1, Efthymios Papageorgiou1, Nicole A. Torquato2, Bining Tian2, Bruce E. Cohen2✉, Mekhail Anwar3✉

1. Department of Electrical Engineering and Computer Sciences, University of California Berkeley, Berkeley CA
2. The Molecular Foundry, Lawrence Berkeley National Laboratory, Berkeley, CA
3. Department of Radiation Oncology, University of California San Francisco, San Francisco, CA

Citation:
Najafiaghdam H, Papageorgiou E, Torquato NA, Tian B, Cohen BE, Anwar M. A 25 micron-thin microscope for imaging upconverting nanoparticles with NIR-I and NIR-II illumination. Theranostics 2019; 9(26):8239-8252. doi:10.7150/thno.37672. https://www.thno.org/v09p8239.htm
Other styles

File import instruction

Abstract

Graphic abstract

Rationale: Intraoperative visualization in small surgical cavities and hard-to-access areas are essential requirements for modern, minimally invasive surgeries and demand significant miniaturization. However, current optical imagers require multiple hard-to-miniaturize components including lenses, filters and optical fibers. These components restrict both the form-factor and maneuverability of these imagers, and imagers largely remain stand-alone devices with centimeter-scale dimensions.

Methods: We have engineered INSITE (Immunotargeted Nanoparticle Single-Chip Imaging Technology), which integrates the unique optical properties of lanthanide-based alloyed upconverting nanoparticles (aUCNPs) with the time-resolved imaging of a 25-micron thin CMOS-based (complementary metal oxide semiconductor) imager. We have synthesized core/shell aUCNPs of different compositions and imaged their visible emission with INSITE under either NIR-I and NIR-II photoexcitation. We characterized aUCNP imaging with INSITE across both varying aUCNP composition and 980 nm and 1550 nm excitation wavelengths. To demonstrate clinical experimental validity, we also conducted an intratumoral injection into LNCaP prostate tumors in a male nude mouse that was subsequently excised and imaged with INSITE.

Results: Under the low illumination fluences compatible with live animal imaging, we measure aUCNP radiative lifetimes of 600 μs - 1.3 ms, which provides strong signal for time-resolved INSITE imaging. Core/shell NaEr0.6Yb0.4F4 aUCNPs show the highest INSITE signal when illuminated at either 980 nm or 1550 nm, with signal from NIR-I excitation about an order of magnitude brighter than from NIR-II excitation. The 55 μm spatial resolution achievable with this approach is demonstrated through imaging of aUCNPs in PDMS (polydimethylsiloxane) micro-wells, showing resolution of micrometer-scale targets with single-pixel precision. INSITE imaging of intratumoral NaEr0.8Yb0.2F4 aUCNPs shows a signal-to-background ratio of 9, limited only by photodiode dark current and electronic noise.

Conclusion: This work demonstrates INSITE imaging of aUCNPs in tumors, achieving an imaging platform that is thinned to just a 25 μm-thin, planar form-factor, with both NIR-I and NIR-II excitation. Based on a highly paralleled array structure INSITE is scalable, enabling direct coupling with a wide array of surgical and robotic tools for seamless integration with tissue actuation, resection or ablation.

Keywords: intraoperative imaging, upconverting nanoparticle, time-resolved imaging, NIR excitation


Citation styles

APA
Najafiaghdam, H., Papageorgiou, E., Torquato, N.A., Tian, B., Cohen, B.E., Anwar, M. (2019). A 25 micron-thin microscope for imaging upconverting nanoparticles with NIR-I and NIR-II illumination. Theranostics, 9(26), 8239-8252. https://doi.org/10.7150/thno.37672.

ACS
Najafiaghdam, H.; Papageorgiou, E.; Torquato, N.A.; Tian, B.; Cohen, B.E.; Anwar, M. A 25 micron-thin microscope for imaging upconverting nanoparticles with NIR-I and NIR-II illumination. Theranostics 2019, 9 (26), 8239-8252. DOI: 10.7150/thno.37672.

NLM
Najafiaghdam H, Papageorgiou E, Torquato NA, Tian B, Cohen BE, Anwar M. A 25 micron-thin microscope for imaging upconverting nanoparticles with NIR-I and NIR-II illumination. Theranostics 2019; 9(26):8239-8252. doi:10.7150/thno.37672. https://www.thno.org/v09p8239.htm

CSE
Najafiaghdam H, Papageorgiou E, Torquato NA, Tian B, Cohen BE, Anwar M. 2019. A 25 micron-thin microscope for imaging upconverting nanoparticles with NIR-I and NIR-II illumination. Theranostics. 9(26):8239-8252.

This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/). See http://ivyspring.com/terms for full terms and conditions.